ODO Building Services has extensive experience delivering commercial electrical projects on time and on budget. Fan installations, rooftop plant connections, three-phase supplies and emergency lighting โ all fully documented, tested and certified.
What We Do
๐ข
Office Fit-Outs
Full electrical fit-outs for new and refurbished commercial units, from first fix through to final testing.
๐
Three-Phase Power
Three-phase distribution boards and supplies for machinery, plant and heavy-load equipment.
๐ฌ๏ธ
Smoke Vent & Fan Systems
Wiring and isolation for smoke vent extract fans and rooftop plant, compliant with fire safety standards.
๐ก
Emergency Lighting
Emergency and escape lighting circuits, installed and certified to keep premises compliant.
๐ฅ๏ธ
Data & Server Room Power
Dedicated spurs and containment for data centres and server rooms, labelled and tested.
๐งฐ
Cable Containment
Cable tray, trunking and conduit systems installed to a clean, professional standard.
Project Gallery Click any photo to enlarge
Smoke Vent Extract Fan Installation
Installation and connection of smoke vent extract fan โ correctly wired, glanded and labelled to BS 7671, ensuring compliant and reliable smoke extraction in the event of a fire.
Rooftop Fan Isolators โ Smoke Vent System
Twin 63A fire-rated isolators mounted on galvanised steelwork, providing local isolation for smoke vent extract fans on the rooftop โ installed to manufacturer specification and fully compliant with smoke control system requirements.
Commercial Ductwork โ Fan Framework & Electrical Installation
Complete electrical installation for rooftop fan system โ bespoke galvanised steel framework fabricated and fixed for fan and isolator mounting, SWA armoured cable pulled and routed on cable tray, 63A fire-rated isolators installed and connected, all tested and ready for commissioning.
Lobby Smoke Vent Fan
Internal termination of lobby smoke vent fan โ labelled, tested and certified on completion.
Three-Phase Distribution Board
Three-phase distribution board supplying machinery, pumps and associated plant equipment โ fully wired, tested and certified to ensure safe and reliable power distribution throughout the installation.
High Voltage Cable Termination
Termination of high voltage cabling inside commercial distribution panel โ colour coded, correctly dressed and glanded to BS 7671.
Data Centre Spur Installation
Installed spur at data centre โ correctly labelled, mounted to galvanised steelwork and tested on completion.
Double Socket with Galvanised Conduit
Double switched socket outlet installed with galvanised steel conduit drop โ clean, precise 2nd fix installation with a professional finish.
Wiska Box Connection
Wiska box installed and connected on cable tray โ IP-rated junction box correctly glanded, wired and secured to galvanised containment.
Intricate Conduit Systems
ODO Building Services specialises in complex and intricate conduit installations โ precision-bent galvanised steel conduit systems designed and executed to the highest standard for any electrical requirement.
Dado Trunking โ Office Installation
Dado trunking installed throughout to provide power and data points across office spaces โ a clean, professional solution allowing full flexibility for desk layouts and future changes.
Intricate Cable Tray Sets
Showcasing our ability to complete intricate cable tray sets โ precisely fabricated and installed to navigate complex structural layouts, delivering a clean and professional finish every time.
Cable Tray System
Perforated cable tray system installed across a large commercial ceiling โ multi-directional runs with clean fabricated junctions, providing a structured containment network for all cabling throughout the building.